| Model | Capacity | Size | Height | Bus Type | Int.Type |
| Fujitsu M2244SA | 67MB | 5.25" | FHT | SCSI1 | SE |
M2244SA FUJITSU
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 5.25"/FH Cylinders 823| | |
Capacity form/uniform 67/ 86 MB Heads 5| | |
Seek time / track 25.0/ 5.0 ms Sector/track 35| | |
Controller SCSI1 SINGLE-ENDED Precompensation
Cache/Buffer 16 KB Landing Zone
Data transfer rate 1.250 MB/S int Bytes/Sector 512
2.500 MB/S ext SYNC
Recording method RLL 2/7 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 45 | -40 60
Power: sleep W Humidity % 20 80 | 5 95
standby W Altitude km 3.000| 12.000
idle W Shock g 2 | 20
seek W Rotation RPM 3600
read/write 32.0 W Acoustic dBA 45
spin-up W ECC Bit
MTBF h 30000
Warranty Month
Lift/Lock/Park YES Certificates
LayoutFUJITSU M2244/2245/2246-S/SA/SB OEM MANUAL B03P-4805-0202A...01 +------------------------------------------------------+ |+0+1+2+3+10---CN102 +RM57--+ |--+ |+-+-+-+-++----1 +------+ | |-SOLDERED | LED +RM57--+ | | SIDE | COMPONENT +------+ |XX| | SIDE 2-1 2-1 |XX|SCSI | CN105 | |CN104 |XX|INTERFACE | | | | | |XX| | 1615 1615 |XX| | 16-CNH4-+ +CN103 |XX| | 15------1 9----1 |XX| | 16-CNH2--2 |XX| | 15-------1 |XX| | |XX| | |XX| | | |XX Power |16-CNH3-2 16-CNH1---2 | |XX |15------1 15--------1 |--+ +------------------------------------------------------+ JumpersFUJITSU M2244/2245/2246-S/SA/SB OEM MANUAL B03P-4805-0202A...01 Jumper settings x = Jumper set at factory Short plugs are inserted as follows when shipped from the factory. CN105: Between 1 and 2, 3 and 4, 5 and 6, 7 and 8, 9 and 10 CNH2: Between 15 and 16 CNH4: Between 15 and 16 The following settings are model specific.
CNH4: Between 13 and 14: M2246
Between 11 and 12: M2245
No short plug between 11 and 12 or 13 and 14: M2244
Host interface connector signal assignments
--------------------------------------------
Pin number Signal Signal Pin number
--------------------------------------------
01 GND -DB0 02
03 GND -DB1 04
05 GND -DB2 06
07 GND -DB3 08
09 GND -DB4 10
11 GND -DB5 12
13 GND -DB6 14
15 GND -DB7 16
17 GND -DB8 18
19 GND GND 20
21 GND GND 22
23 GND GND 24
25 (Open) TERMPWR * 26
27 GND GND 28
29 GND GND 30
31 GND -ATN 32
33 GND GND 34
35 GND -BSY 36
37 GND -ACK 38
39 GND -RST 40
41 GND -MSG 42
43 GND -SEL 44
45 GND -C/D 46
47 GND -REQ 48
49 GND -I/O 50
* Power supply for terminator (+5VDC)
CN105 SCSI ID setting
----------------------
SCSI ID 5-6 3-4 1-2
----------------------------
0 OPEN OPEN OPEN
----------------------------
1 OPEN OPEN CLOSED
----------------------------
2 OPEN CLOSED OPEN
----------------------------
3 OPEN CLOSED CLOSED
----------------------------
4 CLOSED OPEN OPEN
----------------------------
5 CLOSED OPEN CLOSED
----------------------------
6 CLOSED CLOSED OPEN
----------------------------
x 7 CLOSED CLOSED CLOSED
A specified ID must be unique on the SCSI bus.
CN105 SCSI parity check option setting
---------------------------------------
7-8 OPEN Disable: IDD does not execute parity check
x CLOSED Enable: IDD executes a parity check
This option specifies whether to enable or disable the SCSI data bus
CN105 Arbitration option setting
---------------------------------
9-10 OPEN Disable
CLOSED Enable
This option specifies whether to enable or disable the Arbitration
CNH4 Device type selection
---------------------------
11-12 13-14
----------------------------------------
M2244S/SA/SB OPEN OPEN
M2245S/SA/SB CLOSED OPEN
M2246S/SA/SB OPEN CLOSED
Setting values are valid when the power is on.
CNH4 Option for motor start control from interface setting
-----------------------------------------------------------
15-16 CLOSED Disable: The spindle motor starts when IDD's
power is turned on.
OPEN Enable: The spindle motor starts by Start/Stop
Unit command
This option specifies whether to enable or disable the function for
LED indicators
--------------
+---+---+---+---+---------------------------------------------+
|L3 |L2 |L1 |L0 | |
+---+---+---+---+-------+ |
|RED| AMBER | COLOR | IDD state |
+---+---+---+---+-------+--------------------+----------------+
|OFF|OFF|OFF|OFF| Operating |LEDs Indicates |
+---+---+---+---+----------------------------+the operation |
|OFF|OFF|OFF|ON | Idle (IDD ready) |status |
+---+---+---+---+----------------------------+ |
|OFF|OFF|ON |ON | In diagnostics | |
+---+---+---+---+----------------------------+----------------+
|OFF|OFF|ON |OFF| Drive error has been de- |LEDs Indicates |
| | | | | tected during diagnosing |the results of |
+---+---+---+---+----------------------------+diagnostics |
|OFF|ON |OFF|OFF| ROM error has been detected| |
| | | | | during operation | |
+---+---+---+---+----------------------------+ |
|OFF|ON |OFF|ON | RAM error has been detected| |
| | | | | during operation | |
+---+---+---+---+----------------------------+ |
|OFF|ON |ON |OFF| Register error has been de-| |
| | | | | tected during diagnosing | |
+---+---+---+---+----------------------------+ |
|OFF|ON |ON |ON | Buffer error has been de- | |
| | | | | tected during diagnosing | |
+---+---+---+---+----------------------------+----------------+
|ON |OFF|OFF|OFF| Drive hard error has been |LEDs Indicates |
| | | | | detected |the fault status|
+---+---+---+---+----------------------------+ |
|ON |OFF|OFF|ON | Spindle motor revolution | |
| | | | | fewer than 90% of standard | |
+---+---+---+---+----------------------------+ |
|ON |OFF|ON |OFF| VCM overcurrent | |
+---+---+---+---+----------------------------+ |
|ON |OFF|ON |ON | Initial seek timeout | |
+---+---+---+---+----------------------------+ |
|ON |ON |OFF|OFF| +12V/+5V, less than 80% of | |
| | | | | standard | |
+---+---+---+---+----------------------------+ |
|ON |ON |OFF|ON | Seek error | |
+---+---+---+---+----------------------------+ |
|ON |ON |ON |ON | Controller hard error | |
+---+---+---+---+----------------------------+----------------+
The 4-bit LED (L3 to L0) indicates the IDD operation status and Operator panel connection
+--+----------+---------------------+
View from +------+ | | Signal | |
cable side | 3 1 | | | Mnemonic |Definition |
of connector| 4 2 | +--+----------+---------------------+
---+------+-- | 1| Z01A |TTL High level |
+--+----------+---------------------+
| 2| *FPTCT |Write Protect Switch |
+--+----------+---------------------+
| 3| 0V |Signal ground |
+--+----------+---------------------+
| 4| *CMDCMP |Ready indicator |
+--+----------+---------------------+
DC Power and pin connector assignments
--------------------------------------
+------------+ pin 1 +12 VDC
-----+ 1 2 3 4 +-- pin 2 +12 Volts Return
+------------+ pin 3 + 5 Volts Return
View from cable pin 4 + 5 VDC
side of connector
InstallFUJITSU M2244/2245/2246-S/SA/SB OEM MANUAL B03P-4805-0202A...1 Notes on installation Drive mounting
horizontally vertically
+-----------------+ +--+ +--+ +------------------+
| | | +-----+ +-----+ | | | x
| | | | | | | | x+----------------+x
+-+-----------------+-+ | | | | | | ||x x||
+---------------------+ | | | | | | || x x ||
| | | | | | || x x ||
x x | | | | | | || x x ||
+------x------x-------+ | +-----+ +-----+ | || xx ||
+-+------x--x-------+-+ +--+ +--+ || x x ||
| xx | || x x ||
| x x | || x x ||
+---x--------x----+ |x x|
x x x++----------------++x
There are three possible installation directions, and the mounting Ambient temperature Air Circulation This head assembly has a closed-loop air recirculation system using DC Grounding Frame Structure System Configuration
+--------+
|HOST (1)| +---------+
| | <-SCSI---+---------> | IDD |
+--------+ | +---------+
|
| +---------+
+---------> | IDD |
| +---------+
|
|
|
|
+--------+ | +---------+ Other SCSI
|HOST (2)| <--------+---------->| | Controller
| | | |
+--------+ +---------+
System configuration example
Recommended parts for connection +------------+-----------------+---------------+--------------+ | |Name |Model |Manufacturer | +------------+-----------------+---------------+--------------+ | Host |Cable Connector |FCN-7007J050- |Fujitsu | | interface |(IDD, closed-end)|AU/B | | | SCSI +-----------------+---------------+--------------+ | |Cable Connector |FCN-707J050- |Fujitsu | | |IDD, throughend) |AU/0 | | | +-----------------+---------------+--------------+ | |Cable |455-248-50 |SPECTRA- | | | | | STRIP | +------------+-----------------+---------------+--------------+ | Drive Power|Cable Connector |1-480424-0 |AMP | | Supply +-----------------+---------------+--------------+ | |Contact |170121-4 |AMP | | +-----------------+---------------+--------------+ | |Cable |AWG-18 | | +------------+-----------------+---------------+--------------+ | SG |Cable faston |62187-1 |AMP | | |receptacle | | | | +-----------------+---------------+--------------+ | |Faston tab for |61761-2 |AMP | | |the IDD | | | | +-----------------+---------------+--------------+ | |Cable |AWG20 | | +------------+-----------------+---------------+--------------+ Connection of components
+-------+-+ +---------+ Power +---------+
|Host | | | IDD1 XxxxxxxxxxxxX Power |
|System |T+---SCSI-+-+ +---+ XxxxxxX Supply |
| +-+ | +---------+ | X XxxxX |
| | | | X X +----+----+
+---------+ | | X X |
| +---------+ | X X |
| | IDD2 Xxxx|xx X |
+-+ +---o---X---FG---+
| +---------+ | X
| F X
| G X
| | X
| | X Power
| +-+--------+ | X
| |T|IDDn Xxx|xxxx
+-+ | +--+
+-+--------+
FG = Frame Ground -- T = Terminator Signal values and electrical levels Signal value Electrical level ------------------------------------------------- TRUE, asserted, on, or 1 Low (0.0 to 0.8 VDC) FALSE, negated, released, High (2.0 to 5.25 VDC) off, or 0 Driver and receiver circuits
The MB463 (Fujitsu) or open collector NAND gate equivalent to
SN7438 (TI) is recommended.
(2) Receiver circuit for signals other than REQ and ACK
A schmitt trigger circuit equivalent to SN74LS240 (TI) is
recommended.
Termination circuit
-------------------
The termination circuit shown in the following figure are installed
in SCSI devices which are connected at both ends of the interface
cable.
+5 VDC
--+--
|
+++ 220 2%
| |
-SIGNAL +++
------------+
+++ 330 2%
| |
GND +++
------------+
+++
Terminators are already installed in IDD a shipment. Remove both Connector Requirements The non-shielded cable connector shall be a 50-conductor connector Cable requirements To minimize discontinuities and signal reflections, cables of FeaturesFUJITSU M2244/2245/2246-S/SA/SB OEM MANUAL B03P-4805-0202A...01 Automatic data error correction Alternate block processing
Media defects
-------------
Cylinder 0, Head 0 and 1 are defect free.
M2244S/SA/SB....85 or fewer (48 or fewer per surface)
M2245S/SA/SB...120 or fewer (48 or fewer per surface)
M2246S/SA/SB...171 or fewer (48 or fewer per surface)
The maximum defect length is 32 bytes.
Controller circuit - Data buffer (8 KB x 2) - SCSI protocol control an data transfer control - Sector format control - ID register - SERDES - ECC - Data comparison and data error correction - Error recovery and self diagnostic Reformatting If it required to use the sector interleaving, or to change the 1) Connect the IDD to be reformatted to the system.
2) If it is required to change the sector size (data block length),
issue a Mode Select command that specifies the new data block
length as shown in the following table, prior to step 3).
+-----------------+ +-------------------+
| CDB | | Parameter |
+-----------------+ +-------------------+
Byte 0 | X'15' | Byte 0 | X'00' |
+-----------------+ +-------------------+
1 |0 0 0 1 0 0 0 0 | 1 | X'00' |
+-----------------+ +-------------------+
2 | X'00' | 2 | X'00' |
+-----------------+ +-------------------+
3 | X'00' | 3 | X'08' |
+-----------------+ +-------------------+
4 | X'0C' | 4 | X'00' |
+-----------------+ +-------------------+
5 | X'00' | 5 | X'00' |
+-----------------+ +-------------------+
6 | X'00' |
+-------------------+
7 | X'00' |
+-------------------+
8 | X'00' |
+-------------------------------+ +-------------------+
|X'000100' for 256 bytes/sector| +-- 9 |Block Length (MSB) |
+-------------------------------+ | +-------------------+
|X'000200' for 512 bytes/sector+>| 10 |Block Length |
+-------------------------------+ | +-------------------+
|X'000400' for 1024 bytes/sector| +-- 11 |Block Length (LSB) |
+-------------------------------+ +-------------------+
3) Issue a Format Unit command with the desired Interleaving Factor.
Format unit command for reformatting
------------------------------------
+-----------------+
| CDB |
+-----------------+
Byte 0 | X'04' |
+-----------------+
1 |0 0 001 0 0 0 0 |
+-----------------+
2 | X'00' |
+-----------------+
3 | X'00' |
+-----------------+
4 |Interleave Factor|
+-----------------+
5 | X'00' |
+-----------------+
The disk medium is reformatted with the specified block length and Sector Interleaving Data buffer Low power consumption Low noise and low vibration Start and stop time Reliability Mean Time To Repair (MTTR) Service Life Spindle Motor |
| HOME | Fujitsu drives | All Hard Drives |
|
|