| BASF 6185 | |
| Specifications | |
| basf 6185 Specifications |
| Model | Capacity | Size | Height | Bus Type | Int.Type |
| BASF 6185 | 23MB | 5.25" | FHT | MFM | ST506 |
6185 BASF MAGNETICS
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 5.25"/FH Cylinders 440| | |
Capacity form/unform 22/ 28 MB Heads 6| | |
Seek time / track 81.0/15.0 ms Sector/track 32| | |
Controller MFM / ST412 Precompensation 128
Cache/Buffer KB Landing Zone 439
Data transfer rate 0.625 MB/S int Bytes/Sector 256
0.625 MB/S ext
Recording method MFM operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 4 50 |
Power: sleep W Humidity % 15 80 |
standby W Altitude km |
idle W Shock g |
seek 23.0 W Rotation RPM 3600
read/write 18.0 W Acoustic dBA
spin-up W ECC Bit
MTBF h 11000
Warranty Month
Lift/Lock/Park NO Certificates
LayoutBASF 6185 TECHNICAL MANUAL 80307-069 JULY 1984 +-----------------------+
P61 | +-------+ |XXX J3
---------------++-+ |LM339 + |XXX Power
++++ +-------+ |XXX
+--+ |
Option Switch |XXX
+------------+ |XXX
|++++++++++++| |XXX J1
|++++++++++++| |XXX
+-----------1+ +-+ |XXX
+-------------+ +-+ |XXX
|898-5-220/330| Option |+-+
|1F Terminator+ Ground || | J5
+-------------+ |+-+
|XXX
|XXX J2
|XXX
XXX
------------------------------------------+
JumpersBASF 6185 TECHNICAL MANUAL 80307-069 JULY 1984 Jumper Setting User selectable options +-----+
1|xxxxx| Drive Select 1
2|xxxxx| Drive Select 2
3|xxxxx| Drive Select 3
4|xxxxx| Drive Select 4
5|xxxxx| PERM SEL D
6|xxxxx| MTR ON by power on
+-----+
Termination Termination for the "A"-cable control lines is contained in a DIP- Grounding The mounting frame is isolated by the rubber shock absorbers from the Drive Address Selection The drive address assignment us independent of the drive's position Spindle Motor Start Control If switch 6 is ON the spindle motor is started as soon as power is If switch 6 is OFF the spindle motor does NOT start with power on. It Automatic Rezero Permanent Selection Permanent selection may not be used in a daisy-chain configuration If switch 5 is in the OFF position, selection of the drive is under InstallBASF 6185 TECHNICAL MANUAL 80307-069 JULY 1984 Notes on Installation Mounting Installation direction horizontally vertically
+---------------------+ +--+ +--+
+-+ +-+ | +-----+ +-----+ |
| | | | | | | |
| | | | | | | |
+-----------------+ | | | | | |
| | | | | |
| | | | | |
| +-----+ +-----+ |
+--+ +--+
The BASF 6185 may be mounted in three different orientations. When The following general recommendations for mounting the drive in a - The drive should be mounted with four screws, either to the four bottom mounting holes or to the four mounting holes on the two sides. - A clearance of at least 4 millimeters should be provided in all directions around the HDA. This space is required to allow the HDA to swing on the shock absorbers if the system is exposed to external vibrations or shocks. - The mounting of the drive must allow sufficient air flow for its cooling. The environmental temperature specified for the drive refers to the air directly surrounding the drive. This value (50 degr. C) must not be exceeded under any operating condition or temperature outside of the system. - If the drive is mounted close to devices which radiate a very high level of electrical noise (such as switched mode power supplies, CRT displays etc.) it may be advisable to provide a shielding be- tween those devices and the disk drive. Initial power on - Set the option switches as follows: 1 - 5 OFF
6 ON
- Install or remove the terminator pack as required. - Verify that the connectors of all interconnect cables in the drive are firmly seated. - Mount the drive in the system. If the drive is tested outside the system, make sure that the recommended mounting orientations are still met. - Verify that the interface signal and power cables are correctly wired. (Reserving of the two power supply voltages would cause severe damage to the drive.) - Connect the interface signal and power cable. If interface cables without polarization keys are used, verify that the interface connectors are installed in the correct orientation. - Remove the adhesive tape from the spindle motor. - Provide power to the drive. Watch that the brake is disengaging and the spindle motor is starting to rotate. Wait until the spindle motor has reached full speed. - Watch that the drive performs the automatic rezero after the spindle is at full speed. - Turn power off, watch that the brake is engaging. - Set the option switches as required for normal system operation. - Perform a normal system power on procedure. Connecting Cables The "A"-cable has 34 lines and is used for transfer of control and The "B"-cable has 20 lines and is mainly used for transfer of read/ The power cable should always be connected in radial mode in order to Connectors The "B"-cable is connected through the 20 pin connector J2 to the The power cable is connected through the 4 pin connector J3 to the drive. The recommended mating connector is AMP P/N 1-480424-0 with pins P/N 350078-4 or equivalent. /-+ | 1| +12V DC | 2| GND 12V | 3| GND 5V | 4| +5V DC \-+ FeaturesBASF 6185/6 TECHNICAL MANUAL 80307-069 JULY 1984 Model and Operation |