DEC RD53-A HARD DISK DRIVE REPAIR, DEC RD53-A HARD DISK DRIVE SPECIFICATIONS,
DEC RD53-A hard disk drive sales, DEC RD53-A hard disk drive repair, DEC RD53-A hard disk drive specifications, 
DEC RD53-A Hard Disk Drive Repair, DEC RD53-A Hard Disk Drive Specifications, DEC RD53-A DEC RD53-A
Specifications



Click on pictures for larger view.


DEC RD53-A Specifications
Model Capacity Size Height Bus Type Int.Type
DEC RD53-A 72MB 5.25" FHT MFM ST506

DEC RD53-A
DEC RD53-EA Specifications
Size 5-1/4 Inch
Interface ST-506/412
Interface Type    
Encoding Method MFM (Modified Frequency Modulation)
Formatted Capacity 71.3
Disks 5
Heads 8
Cylinders 1024
Sectors 17
Buffer Size N/A
Average Seek 28 ms
Single Track 6 ms
Rotation Speed/Avg. Latency 3600 rpm +/- 0.5%
Transfer Rate to / from. media 5 Mbits/sec
Transfer Rate to / from buffer N/A
Tracks Per Inch (TPI)  
Bits Per Inch (BPI)  
Dimensions 8.0"L x 5.75"W x 3.25"H
Weight 5.75 lbs.

POWER REQUIREMENTS
+12V +/-5% +5V +/-5% Power
Spin up   3.9A (max)    
Read / Write   2.0A avg  0.9A avg  
Typical      32 Watts

Notes:
Drive Addressing and Interface Termination


DS1, DS2, DS3, DS4 Drive Select Jumpers
  The Drive Select jumper locations are identified as DS1, DS2, 
  DS3, and DS4. Only one Drive Select jumper is installed on a 
  drive. The drives are shipped with the jumper installed at DS1.
  For every drive in a PC/AT installation, move the jumper from DS1
  to DS2 (the special twisted interface cable that is generally
  used takes care of assigning a unique address to each drive).
  Some other systems may require that each drive be jumpered to a
  unique address (i.e., different DS numbers).

RN1 Interface Terminator
  The Interface Terminator factory installed at RN1 provides proper
  termination for the interface lines. When daisy-chaining multiple
  1320 drives, leave the terminator in the last physical drive on
  the daisy chain cable; remove the terminator from each of the
  other drives. In most PC/AT installations, the C: drive is
  actually at the end of the cable and should retain the
  terminator.

W1 Write Fault Latch
  W1 is the Write Fault Latch. If W1 is present and the drive
  encounters a write fault, all writing to the drive is inhibited
  until after the drive has been de-selected. If W1 is absent,
  fault conditions are not latched. Drives are shipped with a
  jumper installed at W1; remove it for PC/AT installations.

W2 is always installed.

W7 is never installed.

W8 is always installed.

All manufacturer's Names, Logos and trademarks are the properties of the respective manufacturer.


HOME DEC drives All Hard Drives


Check our Media Store for all your Floppy Disk and Tape Supplies.


Contact us

Copyright © 1997 - 2011 Erv Fleckstein ( M. Farris & Associates ). All Rights Reserved.